Physical Character |
Displayer: 12.1" color TFT LCD screen with maximum 8-waveform display |
| Battery : Rechargeable high-energy built-in battery |
Advanced streamline outline design, portable, compact, lightweight |
Operating menu with multi-language interface selection: English, Spanish, Portuguese, Chinese, etc |
| Easy operation with user friendly menu structure design and rotary dial |
| Multi-modes selection for different animals |
Optional built-in wireless networking function
|
| Three-application mode: monitoring, diagnosis, operating. |
WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible |
72 hours data storage . |
| Intelligent audio and visual comprehensive alarm |
| In-hospital applications include emergency pre-and post-operative care, ambulatory surgery, intermediate care/step down units, labor and delivery, and hospital-based special procedure areas |
| Suitable for veterinary use in physicians' offices, clinics, outpatient surgical centers, extended care facilities and other patient care areas, which of require affordable monitoring |
| Suitable for large, middle, small different animal |
Technical Parameter
|
Temperature (surface and rectal)
Measurement range: 25 - 45 ?
Accuracy: ± 0.1 ?
Resolution: 0.1 ?
response time: = 3 min.
ECG
Input: 5 wires ECG cable
Lead section:?,?,?/ aVR, aVL, aVF/ V, MCL1
Gain ( mm/mV ) : 1/4 , 1/2 , 1 , 2 , 4
Frequency response: Diagnosis 0.05 - 100Hz
Monitor 0.5 - 40 Hz
Surgery 1.0 - 25 Hz
Sweep speed(mm/sec): 12.5, 25, 50
Heart rate range: 15-380 BPM
Heart rate accuracy: ± 1 %
ST segment deviation analysis: -0.8-+0.8mV
ST accuracy: ±0.02mv
Respiration Rate( RA-LL impedance and nasal cavity)
Measurement range: 0 - 120 BPM ( adult )
Accuracy: ± 1 BPM or 5 %
Resolution: 1 BPM
|
Power requirements
Input: 98 ~ 260 V AC, 50/60Hz
Consumption: = 80VA
Environment
Operation Storage
Temperature 0.5 - 40 ? -20 - 50 ?
Relative humidity = 80%
Pulse oximeter
SPO2 measurement range: 0 - 100 %
Resolution: 1 %
pulse measurement range: 15-400BPM
Accuracy: ± 2 %
Resolution: 1 BPM
Non-invasive blood pressure
Measurement type : adult, pediatric, neonatal
Measurement range: Systolic 4.0 - 37.0 kPa
Diastolic 1.3 - 33.0 kPa
Mean 2.6 - 35.0 kPa
Accuracy : ± 0.4 kPa or 5 %
Resolution: 0.1 kPa
Protection: over pressure
|
|
Standard configuration |
ECG, HR, PR, SpO2, OxyCRG diagram, ST analysis, Arrhythmia analysis, RESP, NIBP (with venous punch), TEMP*2(surface and rectal type), Drug dose calculation. |
Optional configuration : |
Wireless connection, Recorder and ETCO2. |
| |
|
|