Home        Company          Products        Contact us
   
\
   

Back to main menu

   
 
 
     

S6 Patient Monitor

 
 
 
    
 

Features

l  High resolution 10.4” colorful TFT display, CRT can be connected simultaneously

l  ECG,SPO2,NIBP,RESP,TEMP,HR and BR

l  HRV and 13 kinds of Arrhythmia analysis S-T segment analysis

l  300 seconds ECG waveforms review

l  Maximum 72-hours data records,100 items alarm event records

l  Anti-high frequency electrosurgical equipment

l  Display 9 waveforms maximum in the screen

l  7-lead ECG waveform displayed in one screen simultaneously

l  Adjustable 3-level audio and visual alarm

l  Optional dual-IBP,ET-CO2,built-in thermal recorder

l  Application from adult to neonate

l  Support Ethernet, wired and wireless LAN,compatible with CHOICE central monitoring system

 

Configuration:

Standard: ECG, NIBP, SPO2, RESP, PR, TEMP, Battery, 7-Channel ECG waveforms

Optional: IBP, ETCO2, Thermal array recorder

 

Technical Specification

Safety

Meet the requirements of IEC60601 serials standards, CE marking according to MDD93/42/EEC

Dimension and Weight

Dimension: 335mm (W) × 245mm (H) × 175mm (D)

Weight::   4.0kg without battery;4.8Kg with 1 battery

Operation Environment

Power:       AC100 - 240V (±10%), 50/60 Hz (±3 Hz)

Temperature:  5? to +45?

Humidity:     0%% to 93%, non-condensing

Patient Range

Adult, Pediatric and neonatal

Performance

Display:       10.4?color active matrix TFT

Resolution:      640X480

Trace:         9 waveforms maximum

Indicator:      Power indicator ligh

Battery:       Built-in rechargeable battery

Battery life:    2 hours minimum

Trend time:    1-72 hours

Alarm:        3-level audible and visual alarm

Networking:   LAN / Wireless LAN to CHOICE central station

Wireless LAN: IEEE 802.11b

Recorder:     Built-in, thermal array, 3channels

Recorder width:48mm,(record paper 50mm)

Record speed; 25mm/s

 

ECG

Lead Type:     5-lead or 3-lead selectable

Input:          5-lead: RA; LA; RL; LL; V or R; L; N; F; C

               3-lead: RA; LA; LL or R; L; F

Lead Selection: 5-lead: I; II; III; aVR; aVL; aVF; Vx I, II, III, aVR, aVL, aVF, V (n)   

3-lead: I; II; III

ECG Waveform:   2 or 7 channels

Gain Selection:    ,0.5, 1.0, 2.0, (mm/mV), auto

Sweep Speed:     12mm/s, 25mm/s, 50mm/s

Heart Rate Range: Adult: 15-300 bpm

Pediatric / Neonatal: 15-300 bpm

Accuracy:         ±1 bpm or ±2%, whatever is greater

Resolution:        1 bmp

Bandwidth:        Diagnostic mode: 0.05-100Hz

Monitor mode:  0.5-75Hz

Operation mode: 1-25Hz

Calibration signal: 1mv ± 5% 

CMRR:          >80dB

S-T detection:    YES

Measurement range: -1.2mV---+1.2mV

Arrhythmia analysis: YES

Alarm:            YES, audible and visual alarm

Respiration

Method:             RA-LL impedance

Measurement Range: 0-100 rpm

Resolution:        1 rpm

Accuracy:         ±2% or ±2 rpm, which is greater

NIBP

Method:          Oscillometric

Operation Modes:  Manual/Automatic/STAT

Measurement Unit: mmHg/kpa selectable

Measurement Types: Systolic, Diastolic, Mean

Measurement Range: Adult: 10-270mmHg

                  pediatric 10-200 mmHg

                  Neonatal: 10-135 mmHg

Over-pressure protection: YES

Resolution:            1 mmHg

Temperature

Scale:              °C and F selectable

Measurement Range: 0-50°C

Resolution:          0.1°C or 0.1F

Accuracy:           ±0.1°C, exclusive of probe errors

Channel:            1channel/ 2-channel (option)

Alarm Range:       0-50°C

Probes:             resistive:recta and skin YSI 400 series types

SPO2 (CHOICE)

Range:              0-100%

Resolution:          1%

Accuracy:           70~100% ±2%; 0~69% unspecified

Alarm range:         0-100%

Pulse rate:          Range: 0-254 bpm

Resolution: 1 bpm

IBP

Measurement Range:  -50~350 mmHg

Channel:            2 channels

 Sensitivity:      5 uv/v/mmHg

 

Measurement Unit:   mmHg/kpa selectable

Resolution:         1mmHg

Accuracy:          ±1mmHg or ±2%, whichever is greater

Alarm range:        -10~300mmHg

EtCO2

Sampling Method:      built-in side stream sensor

CO2 concentration display range:    0-99 mmHg

Typical CO2 Accuracy: ±3mmHg (0-40 mmHg)

                     ±8% of reading (41-76 mmHg)

                     ±10% of reading (77-99 mmHg)

 
   
 
Copyright © 2006 MARTVI Medical & Hospital Supply