Features |
Single bed and single bulb. |
| .Design according to the electric mechanism of middle-size machine.The function is full and reasonable. |
The high-tension system is of march-past structure.Equipped with afullwave rectification high-voltage generator and independent X-ray tube unit,with large output power and reliable and stable operation. |
Supply voltage V,roentgenoscopy,photograpy KV and stepless adjustable. |
| Equipped with the manostat for filament of X-ray tube and the spacecharge compensator as to ensure the stable and accurate output. |
| Equipped with the capacity limitation and protection circuit and KvmA sinterlock limitation and protection. |
Adopt the digital circuit timer,grade according to R10 prioritycoefficient and can control time exactly |
.Equipped with the capacity limitation and protection circuit and Kv mA s interlock limitation and protection. |
Examining bed is of electirc back rotation and is equipped with vibrating filter-ray device. |
The spot film device of luminescent screen can hold the film jacket of various sizes and can mAke the photograpy of full-film and two sectional films separately |
The upright post has the bottom track only, which is easy while installation
|
|
MAIN TECHNICAL INDEXE
|
ITEM |
CONTENT |
INDEX |
Upright post |
Move lengthwise (along the bottom track) |
1500mm |
Move transverse |
360mm |
Move up and down (along upright post) |
720~ 1720mm (from focus to ground) |
Supply power |
Voltage |
Single phase 380V/220V |
Frequency |
50Hz ± 0.5Hz |
Capacity |
10KVA |
Inner resistance |
380V:2 O ,220V:0.6 O |
MAX.CAPACITY OF PHOTOGRAY
|
SmAll focus |
25mA |
90KV 100KV ? |
1.0s |
Big focus |
50 mA |
90KV 95KV ? |
6.3s |
100 mA |
85KV 90KV ? |
2.5s |
125 mA |
82KV 85KV ? |
1.0s |
|
TECHNICAL PARAMETER
|
ITEM |
CONTENT |
INDEX |
MAx. Dc output voltage 60KV 100KV ? |
|
|
MAx. Dc output current 100mA 125mA ? |
|
|
Roentgenoscopy |
Voltage |
50~90KV ? 500~100KV ? |
Current |
0.5~5mA |
Photograpy |
Voltage |
50~90KV ? 500~100KV ? |
Current |
SmAll focus 15mA and big focus 50, 60, 100mA four grades together |
Dot film |
100mA (fixed) |
Time |
0.04~6.3s,24 grades together |
High-Voltage generator |
Capacity |
100KVA |
X-Ray tube |
Model |
XD4~2.9/100 |
Focus |
Small focus 1.8mm big focus 4.3mm |
Examining |
Rotary angle |
+90 o ~ 0 o ~ -5 o |
Specification of dot film (stomach and intestines photograpy) |
128x 179mm ( 5” X 7” ) |
205x 254mm ( 8” X 10” ) |
254x 305mm ( 10” X 12” ) |
|
note |
As to the products of the technical index with ?,the users can put forward their requirements when they order. |
|